通过对高邮台地电观测区2Km附近工厂漏电对地电场干扰排查和干扰测试分析,以及对造成这种干扰的机理及判定方法的研究,结果表明:用理论计算得到干扰源大致位置之后,再利用架设临时观测点测试的方法就可测算出相对准确的干扰源位置。
Through to the factory leakage is checking in nearly 2 Km on geoelectric field at Gaoyou station and the experimental analysis of interference, as well as Leaded to the interference mechanism and research of interfering estimation. the results show where’s the location of the interference by theoretical computing data , and then set up temporary observation are experiment , measure relatively accurate interference source position.