对延庆台水温观测资料进行分析,发现水温变化与水位变化密切相关;针对观测中出现的一些典型干扰提出一些解决办法:采取在泄流管最高端加装排气管解决憋气问题;在水温地线接入地网前加装电感解决气氡观测造成的干扰问题等,并提出其他一些日常观测须注意的事项。
According to the observation data analysis of Wuliying, changes in water temperature and water level are closely related. In connection with the observation of some typical interference, some solutions are suggested; take in the discharge tube top end installed to solve exhaust breath problem; at the temperature of ground install access network with inductance to solve gas radon observation caused by interference; and some other daily observation of the note.