河北区域地震前兆台网6个地震台站配备DSQ型水管倾斜仪进行地倾斜观测,选取2009—2016年记录的观测数据,对水管倾斜仪两端点一致性进行相关性分析。结果表明:各台站水管倾斜仪同一分量2个端点的相关系数、方差及均值、潮汐参数无显著性差异,相关性较高,表征产出的数据稳定、可靠。
There are 6 seismic stations equipped with DSQ water pipe inclinometer in Hebei regional earthquake precursor network for ground tilt observation. The observation data recorded from 2009 to 2016 which were selected to analyze the correlation between the two ends of the water pipe inclinometer. The results show that there is no significant difference in correlation coefficients, variances, mean values, and tidal parameters at the two ends of the same component of each station's water pipe inclinometer. The correlation is high and the output data are stable and reliable.
2019,40(2): 103-107 收稿日期:2018-05-30
DOI:10.3969/j.issn.1003-3246.2019.02.014
基金项目:河北省地震局2017年度监测、预测、科研三结合课题
作者简介:任俊峰(1971-),男,河北张家口人,工程师,主要从事地震监测工作。E-mail:jfengren17@sina.com
参考文献:
陈佳,陈建国,张跃刚,等. 张家口地震台地形变数字化与模拟资料对比研究[J]. 地震地磁观测与研究,2006,27(6):49-56.
李希亮,陆汉鹏,孟建国,等. 山东水管倾斜仪观测运行分析[J]. 山西地震,2014,(1):5-9.
孙伶俐,蒋玲霞,丁文秀,等. 湖北省水管倾斜仪观测数据变化特征[J]. 地震地磁观测与研究,2016,37(3):102-111.
王梅,牛安福,季爱东,等. 泰安台固体潮平行观测一致性分析及对异常判定的意义[J]. 地震,2007,27(4):43-50.