为内蒙古自治区大沁塔拉地震台地震计安装保温罩,利用台基噪声计算软件,计算保温前后地震观测数据PSD概率密度函数,分析保温罩对地震计的效能,结果发现,保温罩安装后,地震计温度变化平稳,地震观测数据质量提高。
In this research, the thermal insulation covers were installed for the seismometers of Daqintala Seismic Station in Inner Mongolia Autonomous Region. And we used the PSD probability density function of seismic observation data before and after thermal insulation that was calculated by using the calculation software of base noise to analyze the effect of thermal insulation cover for seismometer. The result suggested that the seismometer temperature changed smoothly and the quality of seismic observation data was improved.
2019,40(2): 131-134 收稿日期:2017-12-25
DOI:10.3969/j.issn.1003-3246.2019.02.018
基金项目:内蒙古自治区地震局局长基金课题(课题编号:2018JC02)
作者简介:安全(1988-),男,工程师,主要从事地震观测仪器维护工作
参考文献:
安全,张建中,苏日亚,等. 利用CWQL检测JOPENS5.2系统仪器参数正确性[J]. 地震地磁观测与研究,2017,38(2):138-142.
王晓蕾,朱小毅,薛兵,等. 温度对甚宽频地震计性能的影响[J]. 地震地磁观测与研究,2012,33(3/4):257-263.
王晓蕾. 温度对甚宽频地震计的性能及输出影响的研究[D]. 北京:中国地震局地震预测研究所,2012.
谢剑波,何寿清,吕金水,等. 宽频带地震计的安装[J]. 地震地磁观测与研究,2007,28(1):57-63.
赵龙梅,高业欣,燕云,等. 温度对甚宽带地震计零点及灵敏度的影响[J]. 防灾减灾学报,2017,33(1):36-39.
中国地震局监测预报司. 测震学原理与方法[M]. 北京:地震出版社,2017.