针对无人值守地震台站逐年增加,运行维护模式不佳的现状,设计一种远程电源监控系统,采用远程电源控制模块,设计软件通过TCP/IP协议,在仪器出现死机时,远程实现设备的断电重启。本文对该系统的设计思路、硬件构成进行描述,并简要介绍软件功能设计、监控告警以及该系统在无人值守台站的应用。实践证明,该系统可有效解决因仪器死机造成的观测数据缺记,为地震专业设备的可靠运行和及时维护提供依据与保障,为今后地震台站,特别是无人值守台站的维护提供借鉴。
In view of the present unattended station increased year by year, shortage of station operation maintenance mode, a remote power control system is designed. The system adopts the remote power management module, and design the software via TCP/IP protocol implementation of equipment under the condition of the instrument to crash the remote power to restart. In this paper, the design of the system, hardware, and briefly introduces the software design, function, monitoring, alarm, and the system application at Jingle Seismic Station. Practice has proved that the system can effectively solve the observation data from instrument crashed short of remember, for the reliable operation of the professional equipment and provide basis for timely maintenance and security; Also for the future seismic stations, especially the unattended station maintenance for reference.
2019,40(6): 152-159 收稿日期:2018-03-27
DOI:10.3969/j.issn.1003-3246.2019.06.022
基金项目:中国地震局“监测、预报、科研”三结合课题(项目编号:CEA-JC/3JH-170502);山西省地震局科研项目(项目编号:SBK-1817)
作者简介:李惠玲(1980-),女,高级工程师,主要从事地震监测工作。E-mail:king_ling@126.com
*通讯作者:高云峰(1979-),男,工程师,主要从事地震监测工作。E-mail:75704125@qq.com
参考文献:
胡玉良,程冬焱,李惠玲,等. HostMonitor监控软件在山西地震前兆台网的应用[J]. 地震地磁观测与研究,2016,37(1):131-135.
刘其寿,廖春奇,郑永通,等. 无人值守地震台站通信设备电源改造[J]. 华北地震科学,2015,33(4):59-61.
唐磊,丘泽华,郭燕平,唐小勇,徐斌. 无人值守钻孔应变台站的运行模式及探讨[J]. 震灾防御技术,2015,10(2):405-411.