利用恒温水浴仪可以控制水氡样品的温度保持恒定,在恒温条件下进行脱气观测,可以保证水氡测值的稳定性。为验证该方法是否适用于漳州龙师井(水温年均值97℃)水氡观测,将同一水样,利用恒温水浴仪,将水温分别控制在20.0℃、22.5℃、25.0℃、27.5℃、30.0℃,进行一系列比测实验,结果表明:在25.0℃-27.5℃的恒温条件下,氡浓度测值更为稳定,变化更小,可进一步提高水氡观测的质量和稳定性,说明在龙师井采用恒温脱气方法是可行的。
Constant temperature water bath instrument can keep the temperature of water radon sample constant. Deaeration under a constant temperature condition can guarantee the stability of the measurement of water radon. To verify whether this method is suitable for the water radon observation in Longshijing, Zhangzhou (annually average water temperature is 97℃), we take the same water sample and utilize the constant temperature water bath instrument to keep the water temperature at 20.0℃, 22.5℃, 25.0℃, 27.5℃ and 30.0℃, respectively to carry out a series of contrast test experiments. The results show that measured radon potency is more stable under 25.0℃ -27.5℃ constant temperature conditions with smaller changes and is able to further improve the quality and stability of water radon observation, indicating that it is feasible to adopt the constant temperature degas method in Longshijing.
2020,41(5): 118-121 收稿日期:2020-04-10
DOI:10.3969/j.issn.1003-3246.2020.05.017
基金项目:福建省地震局台站基金——福建水氡恒温脱气观测的实验研究(项目编号:T201409)
作者简介:朱继承(1978-),男,工程师,主要从事地震地下流体监测预报工作。E-mail:303217013@qq.com
参考文献:
刘学领,马建英,邵永新,等. 水样的处理方法对水氡观测影响的探讨[J]. 地震地磁观测与研究, 2007, 28(6):49-52.
刘学领,马建英,程立康,马丽丽. 水氡观测样品脱气温度及观测时间的选取[J]. 地震地磁观测与研究, 2008, 29(2):55-58.
尤宇星. 温差对泉州四至井水氡测值的影响分析[J]. 华北地震科学, 2011, 29(3):57-60.
张翊宁,陈莹. 福建省水氡观测资料变化规律与稳定性评定[J]. 华南地震, 2005, 25(4):66-72.
朱继承,林国元. 福州乌鸦嘴泉水氡恒温脱气观测的实验研究[J]. 华南地震, 2015, 35(3):72-76.